메뉴 바로가기 본문 바로가기

Ai eca3Gremote consultation

메인 콘텐츠

Ground leaps towards 100 years of dream

100% lightning protection,

100% guarantee

Ground leaps towards 100 years of dream

100% lightning protection,

100% guarantee

01
02
Introduction

Korea’s No. 1 lightning protection

Proven through performance

20,000

Delivered to over 20,000 places nationwide(2024)

99.88%

99.88% Lightning protection success rate

100%

100% Guarantee

PRODUCT

eca3G

100% lightning protection, 100% guarantee, 10 years of persisting period
Up to 10 years of performance and quality assurance through PGS service agreement!

PRODUCT

TNC

TNC grounding system without
laying grounding electrode in the site

PRODUCT

PQR

Electric shock prevention between electric train and
PSD & PSD equipment lightning/surge protection system

PRODUCT

3D grounding device

DC Decoupling Device is a device that protects insulation facilities of piping system lay underground from electrical corrosion (electric type)

PRODUCT

0N-365 Monitoring SYSTEM

eca3G lightning protection integrated management monitoring system that monitors the performance/operation of integrated system, equipotentiality and TNC, and leakage current, and provides data analysis information

service

Free Special Inspection

As a specialist in lightning protection and electric safety, Ground provides special PGS inspection service to protect customer’s equipment and inspect the system.

SOLUTION

We solve your problems

Lightning damage prevention measures
  • Lightning damage prevention measures

    Electronic equipment is damaged, breaks down, or malfunctions whenever lightning strikes. Electronic equipment breaks down even if there is no lightening around. Earth leakage breaker trips and causes damages due to blackout whenever lightning strikes. CCTV, fire alarm controller, communication facility, and security system break down or malfunction whenever it rains. Electronic equipment breaks down or malfunctions frequently with no apparent reason. Lightning damage occurs despite the lightning rod, grounding, and SPD. There is significant recovery cost, loss of manpower, financial loss, and work damage due to lightning damage

  • What is the root cause of lightning damage?

    Lightning rod pulls lightning, and grounding provides the entry for electricity. KSC-IEC was amended from independent ground to common ground in 2005, but it is still independent ground. Lightning reacts electrically at 300,000km/sec, and does a very wide damage. Lightning electricity breaks electronic equipment down through the land, water pipes, gas pipes, electric wire, or grounding cable. TN ground should be adopted in Korea, but can’t be adopted due to earth leakage breaker. standard common ground based on equipotential theory can’t be configured where there is ELB. It is because it’s difficult to determine or notify what the invisible lightning electricity did. The sites are not well aware because the amended KSC-IEC standard is promoted or trained.

  • What does it mean to dissipate the lightning damage?

    It protects against damage, breakdown, or malfunction of electronic equipment despite lightning. Electronic equipment operates normally despite lightning around, and never breaks down. ELB never trips despite any lightning. CCTV, fire alarm controller, communication facility, and security system operate normally despite any lightning. There is absolutely no breakdown of electronic equipment caused by unknown reason. Electronic equipment can be operated stably without lightning rod and grounding. Lightning damages are completely prevented to protect against recovery cost, manpower, financial and business loss.

  • How can lightning damages be dissipated?

    Solve the crashing issues between KS C-IEC’s TN method and extension regulations (ELB installation). Form common grounding based on equipotential theory and maintain the potential difference within 0.2V. In places with ELB, form TN method from the output through electromagnetic circuit separation. Improve the independent grounding of KS C-9609 in the past to the amended KS C-IEC standard in 2005. “Install lightning protection system (excluding lightning rod) and grounding facility” in Article 18 of the Radio Equipment Regulation. Review the error/problem thoroughly, and determine KS C-IEC standard correctly through perception change.

  • After we completely dissipate your lightning damages, decide to purchase after verification & Validation!

    Maintain the TN method and equipotentiality below 0.1V through TNC model (performance-guaranteed product). In places with ELB, form TN method electromagnetic circuit separation of TNC model. Improve the independent grounding of KS C-9609 in the past to the amended KS C-IEC standard by installing eca3G. “Install lightning protection system (excluding lightning rod) and grounding facility” in Article 18 of the Radio Equipment Regulation by installing eca3G. In case of damage, offer 100% compensation through PL insurance.

Preventive measures against serious disasters such as electric shock due to potential difference, electrocution, etc.
  • What are the types of electric shock due to potential difference or electrocution?

    전동차와 승강장안전문간의 전위차 발생으로 승강장안전문 제어계통 고장(오동작) 발생 전동차와 승강장 시설물(구조체, 승강장안전문 등) 접촉시 아크발생으로 위험요인 발생 전동차 승하차시 이용승객이 전동차와 구조물간 접촉시 전기감전 및 충격 발생 전동차 승하차시 카트가 승강장 연단과 전동차간 접촉시 전기충격에 의한 화재 발생 승강장 물유입시 전동차와 승강장간 전기충격 발생 승강장안전문 및 자동발판 절연파괴 등에 의한 전동차와 접촉시 전기감전 및 충격 발생

  • What is the root cause of serious damages due to potential difference?

    전기철도차량이 선로를 통하여 운행시 레일전위는 필수적으로 발생한다. 2000년대 들어서면서 승강장에는 승강장안전문, 자동안전발판, 각종 통신장비등 많은 전자제어 장비들이 많이 시설되어 전기적인 위험요인 증대 특히 승강장안전문은 전기분야 전원 및 접지계통과 다른 환경으로 구축되어 등전위환경이 구축되어 있지 않아 전위차, 낙뢰, 서지에 취약한 현실. 각종 구조물(승강장안전문 등)에 절연처리를 하였으나 사용년수가 증가하고 절연물 파괴현상 증대로 감전 요인 증가.

  • What does it mean to dissipate the serious disasters due to potential difference?

    한국전기설비규정(KEC)와 EN 표준규격에 다음과 같은 예방대책을 권고하고 있다. 1) 승강장안전문 및 구조물은 등전위본딩 시키고 표면은 견고하게 절연 2) 레일전위를 감소시키기 위해 접지보강 3) 전압제한소자 작용 등

  • What does it mean to dissipate the serious disasters due to potential difference?

    레일전위, 누설전류, N-G간 전위, 허용 접촉전압 기준 범위 아래로 설비를 구성한다. 기준값 이상이면 레일등전위모듈과 서지감쇄모듈을 작동시키도록 설비를 구성한다. N-G간 등전위 모듈을 구성한다. 레일과 승강장안전문 등 승강장 구조물간 전위차 모니터링 설비를 구성한다.

  • After we completely dissipate your serious damages due to potential difference, decide to purchase after verification!

    레일전위, 누설전류, N-G간 전위, 허용 접촉전압 기준을 1V 이내로 관리한다 승강장안전문의 낙뢰나 지락, 서지로부터 제어장치, 전원장치 등을 완벽히 방호한다 eca3G TNC PQR장치를 설치하여 전기철도에서 레일전위, 낙뢰 발생으로부터 안전상 문제점을 완벽히 해결한다. 만약 피해가 발생하면, PL 보험을 통하여 100% 책임배상을 제공한다

The Reality of the Lightning Rod, and lightning protection for electronic equipment, PSD accident prevention measures